CelMate® CO2 Incubators

CelMate® CO2 Incubators

VivoCell™ Precise Temperature, CO2 Control and High Humidity

  • Best uniformity and control among competition
  • Fast CO2, temperature and humidity recovery without overshoot
  • Direct heat design for rapid recovery, with 8 heater grouped into 3 zones
  • Air jacket provides isolation against ambient temperature fluctuations
  • VentiFlow™ forced convection accelerates recovery of chamber air to ISO Class 5 Cleanliness after door closing to prevent contamination
  • Filtered air circulates across water pan to accelerate humidifying process
  • Air flows gently around culture plates, causing no disturbance to cell culture
  • Blower automatically stops when door is opened, to minimize mixing of chamber and room air

Contamination Control System Provides Seamless Protection

  • SteriSafe™ ULPA filtration enables the chamber air to be maintained at ISO class 5 condition.
  • SwiftCon™ moist heat 90oC decontamination cycle operates overnight to eradicate any contamination in the unlikely event it occurs. (Decon cycle time is 20 hours).
  • All input gases are filtered by in-line filters before they enter the chamber to remove impurities and contaminants.
  • The incubator’s main body is made from electro-galvanized steel with Esco’s unique ISOCIDE antimicrobial coating.
  • The interior of the chamber is made from stainless steel type 304.

User-friendly software interface

  • Comprehensive user-configurable alarms for all the parameters.
  • CelAlert™ alarm system reminds user to replace CO2 tank and ULPA filter.
  • Intelligent data and event logger records all incubator parameters for on screen recall.
  • 16 MB built-in flash memory guarantees long term storage of data.
  • Diagnostic interface and on line quick help provide comprehensive solutions to frequently. encountered problems.
  • RS485 data output.

Easy-to-Clean

  • Chamber is made of shiny stainless steel chamber with all rounded corners.
  • Ductwork, plenums and shelves are removable without tools.
  • Glass door is removable without tools.
  • Inner gasket removable without tools.

Easy-to-Service

  • Diagnostic functions in the microprocessor include historical read-out of the parameters.
  • Service can be carried out from the top/front
  • Esco electronics and sensors have been expertly designed and paired to be inherently drift-free, to minimize need for calibration
CelMate® TC Sensor Model
ModelsDescriptions
CLM-170A-8CelMate® Incubator, 170L, TC Sensor, CO2 Control, ULPA,
Moist Heat Decon, 230VAC 50/60HZ (Without Decon Pump)
CLM-170A-9CelMate® Incubator, 170L, TC Sensor, CO2 Control, ULPA,
Moist Heat Decon, 115VAC 50/60HZ (Without Decon Pump)
CLM-240A-8CelMate® Incubator, 240L, TC Sensor, CO2 Control, ULPA,
Moist Heat Decon, 230VAC 50/60HZ (Without Decon Pump)
CLM-240A-9CelMate® Incubator, 240L, TC Sensor, CO2 Control, ULPA,
Moist Heat Decon, 115VAC 50/60HZ (Without Decon Pump)

Options

  •    COA-1001 : Humidity Display, Factory Installed
  •    COA-1001-F : Humidity Display, Field Install Kit
  •    COA-1002 : CO2 Backup (Tank Switcher), Factory Installed
  •    COA-1002-F : CO2 Backup (Tank Switcher), Field Installed
  •    COA-1004 : Reversed Door Swing, Factory Installed
  •    COA-1005 : Analog Outputs, Factory Installed
  •    COA-1005-F : Analog Outputs, Field Installed
  •    COA-1006 : Sealed Inner Door Kit  for 170L (4 Glass Doors With Latches), Factory Installed
  •    COA-1006-F : Sealed Inner Door Kit (4 Glass Doors With Latches), Field Installed
  •    COA-1007 : N2 Backup (Tank Switcher), Factory Installed
  •    COA-1007-F : N2 Backup (Tank Switcher), Factory Installed

Accessories

  •    COA-2001-F : Roller Base (170L)
  •    COA-2019-F : Roller Base (240L)
  •    COA-2002-F : Floor Stand 200mm (8.0") With Adjustable Feet (170L)
  •    COA-2021-F : Floor Stand 200mm (8.0") With Adjustable Feet (240L)
  •    COA-2003-F : Floor Stand 700mm (27.6") With Casters (170L)
  •    COA-2023-F : Floor Stand 700mm (27.6") With Casters (240L)
  •    COA-2005-F : 2-Stage Gas Regulator for CO2/N2
                                      Choose One of The Connectors Below:
                                      1080588 - CGA 320 Connector (US Standard)
                                      1080589 - BP-BS34-#8-NT4 Connector (British Standard)
                                      1080590 - G5/8-RH Connector (China Standard)
  •    COA-2024-F : Extra Shelf (50L, Stainless Steel)
  •    COA-2007-F : Extra Shelf (170L, Stainless Steel)
  •    COA-2025-F : Extra Shelf (240L, Stainless Steel)
  •    OA-2008-F : Stacking Kit (One Set Included With Every Unit Purchased)
  •    COA-2010-F : Electronic CO2 Analyzer, For CO2/O2 Temp Measurement
                                      (With Temp. Probe)
  •    COA-2016-F : Electronic CO2 + O2 Analyzer, For CO2/O2 Temp Measurement
                                      (With Temp. Probe)
  •    COA-2017-F : Electronic CO2 + O2 + RH Analyzer, For CO2/O2/RH/Temp Measurement
                                      (With Temp. Probe)
  •    COA-2011-F : IQ/OQ Documentation
  •    COA-2012-F : 6" Chart Recorder, Temp, 115/230VAC 50/60HZ
  •    COA-2013-F : 8" Chart Recorder, Temp/Temp, 115/230VAC 50/60HZ
  •    COA-2014-F : 6" Chart Recorder, Temp/RH, 115/230VAC 50/60HZ
  •    COA-2015-F : Inner Door Shelving Kit
                                      (4 Sets With Total 12 Mini Shelves For One Incubator)
  •    5250001 : Voyager Software Kit